Item | Description |
Output | Output voltage | 0V to the input voltage |
Output frequency | Low - frequency mode : 0.00Hz to 500.00Hz High - frequency mode : 0.0Hz to 3200.0Hz |
Carrier frequency | 0.8kHz to 16.0kHz (automatic adjustment according to the load) |
Overload capacity | 150% / 1 min |
Input | Voltage/Frequency | 3-phase: 380V; 50/60Hz 1-phase: 220V; 50/60Hz |
the fluctuation of voltage | 3-phase: 380V AC ±15%, allowable range: 323V AC to 437V AC 1-phase: 220V AC ±15%, allowable range: 187V AC to 253V AC |
Frequency range | G type: 110% for long-term, 120% for 22 min, 150% for 1min P type: 105% for long-term, 120% for 8 min, 150% for 1min |
Control Character | Frequency Setting Resolution | Analog Input | 0.025% of maximum output frequency |
| Digital Setting | 0.01 Hz |
Control mode | Voltage/Frequency (V/F) control, Sensorless vector control (SVC) |
Startup torque | SVC | 0.25 Hz/150% |
Speed range | SVC | 1:200 |
Speed stability accuracy | SVC | ±0.5% (SVC) |
Torque boost | Customized boost 0.0 % to 30.0 % |
V/F curve | Straight-line V/F curve, Multi-point V/F curve, Complete V/F separation and Half V/F separation |
Wave current limit | In V/F mode, to achieve fast response and ensure the normal operation of the inverter |
Ramp mode | Straight-line ramp, S-curve ramp Four separate acceleration/deceleration time: 0.1s to 6500s |
Automatic voltage regulation (AVR) | The system maintains a constant output voltage automatically when the grid voltage changes through the permissible range. |
DC injection braking | DC injection braking frequency: 0 Hz to max frequency DC injection braking active time: 0.0s to 100.0s Current level of DC injection braking: 0% to 100% |
Jog running | Frequency range of jog running: 0.00 to max frequency Acceleration/Deceleration time of jog running:0.0s to 6500.0s |
Onboard multiple preset speeds | The system implements up to 16 speeds by using simple PLC function or by using digital input signals. |
Overvoltage and overcurrent stall control | Overvoltage and overcurrent stall control |
Torque limit and control | The system limits the torque automatically. Torque control is applied in vector control. |
(continued) | Undervoltage Restrain during Running | Specially for users with a low or unsteady voltage power grid: even lower than the allowable voltage range, the system can maintain the longest possible operating time based on its unique algorithm and residual energy allocation strategy |
Control input and output signals | Command source | Allows different methods of switching between command sources: Operating panel (keypad & display), Terminal I/O control and Serial communication |
Main frequency reference setting 】channel | Allows different methods of switching between frequency reference setting channels: Digital setting, Analog voltage reference, Analog current reference, Pulse reference(Optional), Communication reference |
|
|
|
|